Galvanic Compatibility: Stainless Steel and Titanium

Galvanic Compatibility: Stainless Steel + Titanium

Low Risk — 0.2V Anodic Index Difference

Stainless Steel (slightly) will corrode preferentially in this pairing.

Compatibility Assessment

A good pairing for high-performance applications. The 0.20V difference is within acceptable limits for most environments. Both metals are corrosion-resistant in their own right.

Property Stainless Steel Titanium
Anodic Index 0.5V 0.3V
Galvanic Role Anode (corrodes) Cathode (protected)
Voltage Difference 0.2V — Low Risk

Compatibility by Environment

The acceptable voltage difference depends on the operating environment:

  • Harsh (outdoor/marine): ⚠️ Use caution (>0.15V)
  • Normal (indoor/uncontrolled): ✅ Compatible (≤0.25V)
  • Controlled (HVAC): ✅ Compatible (≤0.50V)

Thresholds per MIL-STD-889 guidelines. Harsh = saltwater, industrial, outdoor. Normal = warehouse, uncontrolled indoor. Controlled = temperature/humidity regulated.

How Galvanic Corrosion Works

When two dissimilar metals are in electrical contact and exposed to an electrolyte (water, especially saltwater), an electrochemical cell forms:

  1. The more anodic (active) metal — Stainless Steel in this case — loses electrons and corrodes.
  2. The more cathodic (noble) metal — Titanium — is protected and may even corrode less than it would alone.
  3. The corrosion rate increases with the voltage difference between the metals and the amount of moisture present.

The area ratio also matters critically: a small piece of anodic metal in contact with a large cathodic surface will corrode much faster than the reverse. For example, stainless steel rivets in a titanium sheet will fail quickly, while titanium rivets in stainless steel are less problematic.

Prevention Strategies

  • Sacrificial anodes: In critical applications, add a more anodic (active) metal that corrodes preferentially.
  • Design for drainage: Ensure water cannot pool at the junction of dissimilar metals.

Related Metal Pairings

Check any metal combination

Use our Interactive Galvanic Compatibility Checker to test any two metals for galvanic corrosion risk — including anodic index, environment ratings, and prevention recommendations.

FicientDesign Professional

Stop looking it up twice — run the numbers and keep the record.

This reference is free forever. When you need to actually calculate, document, and defend the result, do it in the app — then export a clean report you can hand to a reviewer.

  • ✓46 engineering calculators, unlimited
  • ✓Save & reload every calculation
  • ✓Organize work into project folders
  • ✓Branded, PE-stamped PDF reports

Free plan, no credit card. Upgrade only when it's paying for itself.