Galvanic Compatibility: Copper + Zinc
Severe Risk — 0.9V Anodic Index Difference
Zinc will corrode preferentially in this pairing.
Compatibility Assessment
Extreme galvanic potential. The 0.90V difference will cause rapid zinc corrosion. This is why brass (copper-zinc alloy) can experience dezincification in certain environments.
| Property | Copper | Zinc |
|---|---|---|
| Anodic Index | 0.35V | 1.25V |
| Galvanic Role | Cathode (protected) | Anode (corrodes) |
| Voltage Difference | 0.9V — Severe Risk | |
Compatibility by Environment
The acceptable voltage difference depends on the operating environment:
- Harsh (outdoor/marine): ❌ Not compatible (0.9V > 0.15V)
- Normal (indoor/uncontrolled): ❌ Not compatible (0.9V > 0.25V)
- Controlled (HVAC): ❌ Not compatible (0.9V > 0.50V)
Thresholds per MIL-STD-889 guidelines. Harsh = saltwater, industrial, outdoor. Normal = warehouse, uncontrolled indoor. Controlled = temperature/humidity regulated.
How Galvanic Corrosion Works
When two dissimilar metals are in electrical contact and exposed to an electrolyte (water, especially saltwater), an electrochemical cell forms:
- The more anodic (active) metal — Zinc in this case — loses electrons and corrodes.
- The more cathodic (noble) metal — Copper — is protected and may even corrode less than it would alone.
- The corrosion rate increases with the voltage difference between the metals and the amount of moisture present.
The area ratio also matters critically: a small piece of anodic metal in contact with a large cathodic surface will corrode much faster than the reverse. For example, zinc rivets in a copper sheet will fail quickly, while copper rivets in zinc are less problematic.
Prevention Strategies
- Insulating gaskets/washers: Place non-conductive material between the metals to break the electrical path.
- Protective coatings: Apply paint, lacquer, or specialized coatings to one or both metals.
- Use compatible fasteners: Choose fasteners from the same galvanic group as the base material.
- Apply sealant: Marine-grade sealants (like 3M 5200) can isolate metals while maintaining structural integrity.
- Sacrificial anodes: In critical applications, add a more anodic (active) metal that corrodes preferentially.
- Design for drainage: Ensure water cannot pool at the junction of dissimilar metals.
Related Metal Pairings
- Aluminum + Copper — Severe Risk (0.55V)
- Aluminum + Zinc — Moderate Risk (0.35V)
- Steel + Copper — High Risk (0.5V)
- Steel + Zinc — Moderate (intentional) Risk (0.4V)
- Stainless Steel + Copper — Low Risk (0.15V)
- Copper + Brass — Negligible Risk (0.05V)
Check any metal combination
Use our Interactive Galvanic Compatibility Checker to test any two metals for galvanic corrosion risk — including anodic index, environment ratings, and prevention recommendations.
Stop looking it up twice — run the numbers and keep the record.
This reference is free forever. When you need to actually calculate, document, and defend the result, do it in the app — then export a clean report you can hand to a reviewer.
- ✓46 engineering calculators, unlimited
- ✓Save & reload every calculation
- ✓Organize work into project folders
- ✓Branded, PE-stamped PDF reports
Free plan, no credit card. Upgrade only when it's paying for itself.