Quick Reference — 28 AWG
Diameter: 0.0126″ (0.321 mm)
Area: 0.081 mm² (160 cmil)
Resistance: 64.9 Ω/1000ft (Cu)
Ampacity (75°C): N/AA
Common uses: Electronics, signal wiring, telecommunications, hobby/maker projects
Wire Properties
| AWG Size | 28 AWG |
| Diameter (inches) | 0.0126″ |
| Diameter (mm) | 0.321 mm |
| Cross-sectional area | 0.081 mm² (160 circular mils) |
| Resistance — Copper | 64.9 Ω per 1000 ft @ 20°C |
| Resistance — Aluminum | 106.0 Ω per 1000 ft @ 20°C |
| Weight (copper) | ~0.5 lb per 1000 ft |
Ampacity
28 AWG is below the NEC Table 310.16 minimum building wire size (14 AWG). It is not rated for branch circuit wiring in buildings. Used for low-voltage, signal, and electronics applications.
Nearby Sizes for Comparison
| AWG | Dia (in) | Dia (mm) | Area (mm²) | Ω/1000ft Cu | Ampacity 75°C |
|---|---|---|---|---|---|
| 26 | 0.0159 | 0.405 | 0.129 | 40.81 | — |
| 28 | 0.0126 | 0.321 | 0.081 | 64.9 | — |
| 30 | 0.0100 | 0.255 | 0.0509 | 103.2 | — |
⚠️ AWG Sizing Reminder
- In AWG, lower numbers = thicker wire. 4 AWG is much thicker than 14 AWG.
- Each 3-gauge decrease doubles the cross-sectional area (e.g., 11 AWG ≈ 2× the area of 14 AWG).
- Each 6-gauge decrease doubles the diameter.
- Always follow local electrical codes — NEC values are minimum requirements.
Calculate voltage drop for your circuit
FicientDesign Professional
Stop looking it up twice — run the numbers and keep the record.
This reference is free forever. When you need to actually calculate, document, and defend the result, do it in the app — then export a clean report you can hand to a reviewer.
- ✓46 engineering calculators, unlimited
- ✓Save & reload every calculation
- ✓Organize work into project folders
- ✓Branded, PE-stamped PDF reports
Free plan, no credit card. Upgrade only when it's paying for itself.